Home > Buy Now > Wires, Cables & Cable Assemblies > Other Wires, Cables & Cable Assemblies > Optical Automatic Protect System
 


 BC-Optics (HK) LIMITED
 
icon Products

line

icon Company Profile
icon Selling Leads

line

 
Contact us
BC-Optics (HK) LIMITED
[China]
Address:
Buji Town Longbi Road Shenzhen Guangdong China
Phone:
86-0755-84196553
Contact name:
kitty lee
Inquire now










BC-Optics (HK) LIMITED



 
Products

Optical Automatic Protect System

Inquire now

Optical Automatic Protect System

Click to enlarge image

 Model Number BC-IA optical automatic protect system

BC-IA Optical Automatic Protect System

The BC-IA Optical Automatic Protect System (abbr. OAPS) detects the optical power of main equipment or channel by real time to protect optical communication. When the power is under the threshold value which is set by user, the OAPS will switch to standby channel and give warning with current power. If the OAPS detects that the main channel’s power rose over the threshold value, it will switch to main channel and ensure continuous communications.

 

Product Features:

l        Rapidly respond, give warning and LCD display

l        Low insertion loss

l        Real time power detecting, plug and play

l        Recover swiftly

Applications:

l        The optical channel’s protection and recovery of optical communication net

l        Detect multi-channel in optical transmission system

Specifications:

Parameters

Specifications

Operation Wavelength (nm)

1310±50 or 1550±50

Insertion Loss (dB)

≤1.5

Return Loss (dB)

>45

Switch Time (ms)

<20

Adapter

FC/PC *

Optical Power Range (dBm)

-50~+20 *

Measurement Precision (dB)

±0.5

Warning (threshold) Value (dBm)

20 (default, can adjust by user)

Power Supply (V)

DC 48 or AC 220

Power Consuming (W)

<2

Dimension

standard 1U (19 inch) *

Operation Temperature ()

0~60

Storage Temperature ()

-20~70

Note: the ‘’ mean that we can adjust the OAPS to meet user’s demands.

 

 

Luminous power supervision module

1x2 optical switch

 

 

 

 

The Theory Chart of Optical Automatic Protect System:

 

 

 

 

 

 

 

 

 

 

Serial Interface Protocol of Optical Automatic Protect System

 

Order

Realize Operation

Return Value and Format Instruction

pm?#

retain to main route optical power (dbm)

±XX.XX

ps?#

return to standby route optical power (dbm)

±XX.XX

sw?#

return to working channel

When return value is one, work for the main route.

When return value is zero, work for the standby route.

au?#

return to the current working mode

When return value is zero, it is the manual mode.

When return value is one, it is the automatic mode.

sm?#

return to the switching value of main route dbm

±XX.XX

am?#

return to the warning value of main routedbm

±XX.XX

ss?#

return to the switching value of standby routedbm

±XX.XX

as?#

return to the warning value of standby routedbm

±XX.XX

tm?#

return to the warning state of main route

When return value is zero, it is no warning.

When return value is one, it is warning.

ts?#

return to the warning state of standby route

When return value is zero, it is no warning.

When return value is one, it is warning.

sw1#

set access as main route

If set successful, return to ‘OK’.

sw0#

set access as standby route

If set successful, return to ‘OK’.

au1#

set the machine as automatic working mode

If set successful, return to ‘OK’.

au0#

Cancel automatic working mode

If set successful, return to ‘OK’.

am±xx.xx#

set the warning value of main routedbm

If set successful, return to ‘OK’. For example, if set the warning value of main route as -10.50dbm, the concrete order is am -10.50#

Order

Realize Operation

Return Value and Format Instruction

sm±xx.xx#

set the switching value of main routedbm 

 

If set successful, return to ‘OK’. For example, if set the switching value of main route as -20.50dbm, the concrete order is am -20.50#

.as±xx.xx#

set the warning value of standby routedbm

If set successful, return to ‘OK’. For example, if set the warning value of standby route as -10.50dbm, the concrete order is am -10.50#

ss±xx.xx#

set the switching value of standby routedbm

If set successful, return to ‘OK’. For example, if set the switching value of standby route as -20.50dbm, the concrete order is am -20.50#

 

Serial Interface Setup:

     Baud rate: 9600, no parity bit, data bit: 8, stop bit: 1

 

 


Related Keywords: automatic , protect , system , optical